Advanced search


Knowledge area




Filter by:

Publication type

Authors

Issue Years

Publishers

Origin repository

Access Level

Language

Subject

Select the topics of your interest and receive the hottest publications in your email

4 results, page 1 of 1

Determinación Monte Carlo de dosis en cristalino y tiroides durante exámenes de Tomografía de tórax

HECTOR RENE VEGA CARRILLO (2017)

La Tomografía Computarizada (TC) es un método de diagnóstico por imágenes que deposita mayores dosis que otros métodos de radiodiagnóstico. El conocimiento del espectro de los rayos X es importante, ya que está en función directa con la dosis absorbida por el paciente. En este trabajo se estimó el espectro de los rayos X, producidos durante la interacción de electrones monoenergéticos de 130 keV con blanco de Tungsteno, con la finalidad de determinar sus características energéticas a 50 cm del punto focal. El estudio se hizo mediante métodos Monte Carlo con el código MCNP5 donde se modeló el tubo de rayos X de un tomógrafo Siemens SOMATOM Perspective del Hospital General Regional de León, México. En los cálculos se usaron 3x108 historias y se obtuvo una incertidumbre relativa menor al 0.1%. También, se modeló un maniquí de cuello con tiroides, tórax y cabeza que incluyó el ojo, la mesa y gantry con apertura de 70 cm del tomógrafo. Como término fuente se usó el espectro de los rayos X calculado con espesor de corte de 10 mm limitados por colimadores de Pb. El protocolo de exploración de rutina del servicio radiológico fue utilizado para la TC de tórax, el método paso a paso o disparo instantáneo fue simulado moviendo las coordenadas del maniquí para cada corte y movimiento de rotación continuo de 360°. Se usaron 36 posiciones del tubo de rayos X en pasos de 10°. La radiación dispersada en el tórax deposita una dosis de 2.063 mGy en cristalino y 252 mGy en tiroides.

Producción Científica de la Universidad Autónoma de Zacatecas UAZ

Conference object

CIENCIAS FÍSICO MATEMÁTICAS Y CIENCIAS DE LA TIERRA Espectro de Rayos X Monte Carlo MCNP5 TAC

Photon Shielding Features of Quarry Tuff

HECTOR RENE VEGA CARRILLO (2017)

Cantera is a quarry tuff widely used in the building industry; in this work the shielding features of cantera

were determined. The shielding characteristics were calculated using XCOM and MCNP5 codes for 0.03, 0.07, 0.1, 0.3, 0.662, 1, 2, and 3 MeV photons. With XCOM the mass interaction coefficients, and the total mass attenuation coefficients, were calculated. With the MCNP5 code a transmission experiment was modelled using a point-like source located 42 cm apart from a point-like detector. Between the source and the detector, cantera pieces with different thickness, ranging from 0 to 40 cm were included. The collided and uncollided photon fluence, the Kerma in air and the Ambient dose equivalent were estimated. With the uncollided fluence the linear attenuation coefficients were determined and compared with those calculated with XCOM. The linear attenuation coefficient for 0.662 MeV photons was compared with the coefficient measured with a NaI(Tl)-based -ray spectrometer and a 137Cs source.

Producción Científica de la Universidad Autónoma de Zacatecas UAZ

Article

CIENCIAS FÍSICO MATEMÁTICAS Y CIENCIAS DE LA TIERRA Quarry Tuff XCOM MCNP5

Photon and neutron shielding features of quarry tuff

HECTOR RENE VEGA CARRILLO (2017)

The shielding characteristics of quarry tuff (cantera) against photons and 241AmBe neutrons, were determined.

The effective atomic number of cantera, the Exposure and the Energy absorption buildup factors

for photons in cantera were also calculated. The XCOM code was used to calculate the photon interaction

coefficients. Also, Monte Carlo method was used to model a photon transmission experiment in cantera.

Collided and uncollided photon fluence, Kerma in air, and Ambient dose equivalent were estimated. With

the uncollided photon fluence the linear attenuation coefficients were determined and compared with

those calculated with the XCOM code. The linear attenuation coefficient for 0.662 MeV photons was compared

with the coefficient measured with a NaI(Tl)-based c-ray spectrometer and a 137Cs source. The

Monte Carlo model was also used to estimate the neutron spectra of 241AmBe neutrons in function of cantera

thickness, the Effective and the Ambient dose equivalent for the collided and uncollided neutrons.

Cantera has good shielding properties for low energy photons and poor shielding features against

241AmBe neutrons.

Producción Científica de la Universidad Autónoma de Zacatecas UAZ

Conference object

CIENCIAS FÍSICO MATEMÁTICAS Y CIENCIAS DE LA TIERRA Quarry tuff Shielding Photons Neutrons 137Cs 241AmBe MCNP5 XCOM

Simulación Computacional con MCNP para la Determinación de Dosis en Cristalino y la Tiroides en Estudios de Tomografía Computarizada de Tórax

BASILIA QUISPE HUILLCARA (2018)

La Tomografía Computarizada (TC) es un método de radiodiagnóstico por imágenes que deposita mayores dosis que otras técnicas. En este trabajo se estimó el espectro de los rayos X, producidos por la interacción de electrones monoenergéticos de 130 keV al incidir en los blancos de tungsteno, molibdeno y rodio, con la finalidad de determinar sus características energéticas a 50 cm del punto focal. El estudio se hizo mediante cálculos Monte Carlo con el código MCNP5 donde se modeló el tubo de rayos X de un tomógrafo Siemens SOMATOM Perspective del Hospital General Regional de León, México. El espectro calculado muestra una componente continua y otra discreta, para el caso de tungsteno la parte continua se comparó con el espectro calculado con el código SpekCalc con RMS de 0.44, mientras que la parte discreta para los tres blancos se comparó con los espectros del NIST. Se usaron 108 historias y se obtuvo una incertidumbre relativa menor al 0.1%. Se modelo el tomógrafo según las características para la exploración de tomografía de Tórax; con isocentro de 53.5 cm, 70 cm de apertura del gantry y la fuente cilíndrica de ancho de haz de 3cm. Se simulo el cristalino y la tiroides en el maniquí BOMAB. Como término fuente se usó el espectro de los rayos X con blanco de Tungsteno. La estimación de dosis absorbida por radiación dispersa se consideró; 70mAs, tiempo de rotación 0.6 s, tiempo total de 5.71 s y pitch igual a 1. Se encontró que la dosis absorbida que llega al cristalino es de 7.80 ± 0.08 mGy y dosis efectiva de 0.936 ± 0.010 mSv, en tanto que para la tiroides se obtuvo un valor de 76.63 ± 0.78 mGy y 3.07 ± 0.03 mSv. Los valores encontrados de dosis se aproximan a los estimados con dosímetros.

Master thesis

CLE- Maestría en Física CIENCIAS FÍSICO MATEMÁTICAS Y CIENCIAS DE LA TIERRA Tomografía Computarizada Radiodiagnóstico Espectro de Rayos X Monte Carlo MCNP5 TAC