Título
Caracterización eléctrica del lecho del arroyo Guadalupe, Baja California
Electrical characterization of the bed of the Guadalupe Creek, Baja California.
Autor
Armando López Moya
Colaborador
CARLOS FRANCISCO FLORES LUNA (Asesor de tesis)
Nivel de Acceso
Acceso Abierto
Materias
Resumen o descripción
El estudio del acuífero del Valle de Guadalupe (Baja California) es importante pues es una de las fuentes de agua potable de la ciudad de Ensenada y abastece a una de lasprincipales áreas vinícolas del país. Para estimar la distribución de la resistividad eléctrica del subsuelo se aplicaron tres métodos geoeléctricos (VLF (Very Low Frequency), SEV (Sondeo Eléctrico Vertical) y sondeo TEM (Transitorio Electromagnético)) en tres sitios ubicados en el Arroyo Guadalupe. Adicionalmente, en uno de estos sitios se usó el método
dipolo-dipolo de corriente continua. En cada uno de estos sitios existe una heterogeneidad eléctrica que perturba la respuesta uni-dimensional (1-D) de algunos datos. En dos de los sitios la heterogeneidad es antropogénica (un tubo metálico y una cerca con postes metálicos) y en el otro es de naturaleza geológica (una pared aflorante de granito). Con el uso de varios algoritmos numéricos de inversión y modelado en 1-D, 2-D y 2.5-D fue posible estimar la estructura eléctrica del subsuelo en algunos casos o estimar el grado de
distorsión de los datos debido a las heterogeneidades laterales. El método VLF fue muy útil pues indicó la presencia de las heterogeneidades laterales que pudieron pasar desapercibidas por los otros métodos. La impermeabilización del acueducto no es lo suficientemente eficiente como para aislarlo al flujo de corriente
galvánica. Aún así, el SEV cercano a él, estuvo suficientemente alejado como para no ser afectado por su presencia. Los SEV y sondeos TEM resultaron complementarios en varios aspectos. Las altas resistencias de contacto afectaron a algunos SEV más no a los TEM. Las heterogeneidades conductoras afectaron a los TEM pero no a los SEV. La estructura somera de la resistividad está mejor resuelta en los SEV que en los TEM. El problema de equivalencia en el conductor afectó al SEV pero solo marginalmente al TEM. Se recomienda evitar realizar sondeos TEM cerca de cercas con postes de metal. Las cercas con postes de madera aparentemente no presentan problemas. Adicionalmente se reinterpretaron ocho SEV medidos hace más de 20 años por Díaz (1986), todos ellos ubicados a lo largo de un perfil próximo al Arroyo Guadalupe. El
espesor de la cuenca es incierto en la zona central del perfil debido a un fuerte problema de equivalencia en el conductor inferior que afecta a los cuatro SEV ubicados en esta zona.
Studying the Guadalupe Valley (Baja California) aquifer is important because it is one of the sources of drinking water for Ensenada and the supplier of one of the main wine producing areas of the country. In order to estimate the subsurface electrical resistivity three geoelectric methods (VLF (Very Low Frequency), VES (Vertical Electric Sounding), and TEM (Transient Electromagnetic) sounding) were applied at three sites located on the Guadalupe Creek. Additionally, in one of these sites the dipole-dipole method was used. In
each site occurred an electrical inhomogeneity perturbing the one-dimensional (1-D) response of some data. In two sites the inhomogeneity is anthropogenic (a metallic pipe and a fence with metallic posts), and the other is geologic (an outcropping granitic wall). With the use of several inversion and modelling codes in 1-D, 2-D, and 2.5-D we estimated the subsurface resistivity in some cases and in others how much the data are distorted by the lateral inhomogeneities. The VLF method was useful as it showed the presence of lateral inhomogeneities that might be missed by other methods. The aqueduct’s protective cover is not efficient enough as to insulate it to the galvanic current flow. However, the close VES is far enough as to be unaffected by the pipe’s presence. The VES and TEM soundings are complementary in several aspects. The high contact resistances affected some VES but not the TEM soundings. The conductive inhomogeneities affected the TEM data but not the VES. The shallow structure is better resolved by the VES than by the TEM data. The equivalence problem in the conductive layer affected the VES but only marginally the TEM
soundings. Barbed-wire fences with metallic posts should be avoided by TEM soundings; fences with wooden posts apparently pose no problem Additionally, eight VES measured more than 20 years ago by Díaz (1986) were reinterpreted; they are located along a profile next to the Guadalupe Creek. Due to a strong
equivalence problem affecting the lower conductor, the basin thickness is uncertain in four VES located in the central part of the profile. This problem was minimized in one of these soundings (VES 107) by constrainig the model with the basement depth found in a nearby well.
Editor
CICESE
Fecha de publicación
2009
Tipo de publicación
Tesis de maestría
Recurso de información
Formato
application/pdf
Idioma
Español
Sugerencia de citación
López Moya,A.2009.Caracterización eléctrica del lecho del arroyo Guadalupe, Baja California.Tesis de Maestría en Ciencias. Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California.175 pp.
Repositorio Orígen
Repositorio Institucional CICESE
Descargas
2696